Notes:
COMMENTS FROM HEALTH:
FRISCO SQUARE WATER FEATURE:
- MINIMUM DUAL MAIN DRAINS OR GRATES REQUIRED FOR EACH SUCTION PUMP. APPROVED DRAIN COVERS OR GRATES (ASME/ANSI A112.19.8M COVERS NOT HAVING WATER FLOW THAT EXCEEDS THE APPROVED MAXIMUM GALLONS PER MINUTE, GRATES THAT ARE 12 X 12 OR LARGER MAY BE USED BUT CANNOT EXCEED 1.5 FPS THROUGH REMAINING GRATE(S)/DRAINS(S) WITH ONE GRATE/DRAIN BLOCKED 100%.). COVERS AND GRATES MUST HAVE MINIMUM OF 3 FT. SEPARATION BETWEEN INSIDE EDGES OF COVER TO COVER OR GRATE TO GRATE.
- MINIMUM OF FOUR (4) TILE SIGNS PLACED AROUND COPING OF FOUNTAIN, STATING "FOUNTAIN, NO SWIMMING, NO DIVING" (4" LETTER HEIGHT)
- FOUNTAIN DEPTH CANNOT EXCEED 18"
- FINAL APPROVAL PENDING RECEIPT OF APPROVED ENGINEERS LETTER OR PLAN ADDENDUM REGARDING SUCTION SYSTEM FLOW NOT TO EXCEED 1.5 FPS THROUGH REMAINING COVERS/GRATES WITH ONE 100% BLOCKED.
FOUNTAIN / FRISCO CITY HALL