Notes:
POOL & SPA, LA FITNESS
2/28/2005 12:00:00 AM
(2/28/2005 16:23 JS)POOL/SPA MUST COMPLY WITH ORD#02-12-138. PROVIDE GAUGES: VACUUM, PRESSURE INLET, PRESSURE OUTLET, FLOW METER. TURNOVER RATE ON POOL SHALL BE LESS THAN 6 HOURS, TURNOVER RATE ON SPA SHALL BE LESS THAN 30 MINUTES. SEE ATTACHED LIST OF REQUIREMENTS. MIN. DISTANCE FOR MAIN DRAINS SHALL BE 4 FT. SEE NOTES ON PLAN FOR COVER REQS. BATHER LOADS SHALL BE 130-POOL, 15-SPA. LOCATE EMERGENCY PHONE. "NO DIVING" SHALL BE PLACED IN TILE MARKERS AROUND POOL. INSTALL HYDROSTATIC RELIEF VALVE. STEP/BENCH TILES SHALL BE 1'' MIN LOCATED AT LEADING EDGE OF EACH STEP. TWO SETS OF LIFE SAFETY EQUIPMENT SHALL BE PROVIDED. PROVIDE ELECTRICAL DISCONNECT WITHIN SIGHT OF EQUIPMENT, LOCATED AT LEAST 5' FROM WATER'S EDGE. CALL HEALTH AND FOOD SAFETY FOR PRE-PLASTER & POOL FINALS AT 972.335.5580 X155.