Permit Info
Short Description:
BF11-1087-- CNEW / MAIN STREET AND WORLD CUP WAY
Expiration Date:
8/9/2011
Notes:
BF11-1087-- CNEW / MAIN STREET AND WORLD CUP WAY
7/27/2006 12:00:00 AM
Plan review comments:
1. Structural members and assemblies that supports the 1-hour fire rated corridor shall have a 1-hour fire protection rating.
2. 5/8" thk. type "X" gypsum board shall be used on all exterior walls that enclosed a structural column and girders that support the beam.
3. Flour tropper shall not reduced the fire resistance rating of the 1-hour fire rated ceiling assemblies, therefore it should be fire rated.
4. Subject to field inspection.
CONTINGENT UPON COMPLIANCE WITH REVIEW COMMENTS, CODE REQUIREMENT AND PERTINENT LEGISLATIONS.
SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
REFER TO APPROVED PLANS FOR NOTES.
ALL SUBCONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
GOODMAN ADDITION
|
| BF TESTER | ALLEN R. STEVENS | (940)458-2816 | | 301 DEER RUN DR. | SANGER, TX 76266 |
| OWNER | Main Dallas Parkway Crossing, | (214)360-1711 | sremphrey@earthlink.net | 8235 Douglas Ave, #950 | Dallas, TX 75225 |
| MAIL TO | Main Dallas Parkway Crossing, | (214)360-1711 | sremphrey@earthlink.net | 8235 Douglas Ave, #950 | Dallas, TX 75225 |
| APPLICANT | O'BRIEN & ASSOCIATES | (972)788-1010 | | 5310 HARVEST HILL RD | DALLAS, TX 75230 |
| CONTRACTOR | CMG COMMERCIAL CONTRACTING INC | (214)570-0088 | | 2175 MANANA #100 | DALLAS, TX 75220 |
| ELECT. CTR. | TECTON SERVICES INC. (ELECTRIC | (972)792-7807 | LEM@TECTONINC.COM | 13624 FLOYD CIRCLE | DALLAS, TX 75243 |
| GEN. CONTR. | CMG COMMERCIAL CONTRACTING INC | (214)570-0088 | | 2175 MANANA #100 | DALLAS, TX 75220 |
| IRRIGATION | MAVERICK IRRIGATION | (214)245-6832 | | 3839 WEMDON DRIVE | DALLAS, TX 75220 |
| MECH. CTR. | SUBURBAN HEATING & AIR CONDITI | (214)381-1127 | | 3918 PEACHTREE ST | DALLAS, TX 75227 |
| PLUM. CONT. | INNOVATIVE PLUMBING X-12/2006 | (972)442-9403 | | 1903 HWY 78 | WYLIE, TX 75098 |
|
| BACK FLOW FORM REVIEW |
$75.00
|
8/25/2010
|
| Total Fees |
|
Charged: $75.00
Balance Due: $0.00
|
There are currently no reviews on this record.