Permit Info
Short Description:
2409 A/C, 3226 SF, SF / 1 STORY
Notes:
2409 A/C, 3226 SF, SF / 1 STORY
12/18/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
42. PROVIDE SOIL MOISTURE TREATMENT DOCUMENTATION PRIOR TO STARTING CONSTRUCTION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
A). FUTURE SUBMITTALS-- BREAKDOWN SQ.FOOTAGE; A/C SPACE COVERED PATIOS AND PORCHES AND GARAGE B). 2'&10' RULE WILL APPLY AT CHIMNEY C). NEED TO PICK UP CONTRACTORS GUIDELINE AT CITY OF FRISCO D). ELECTRICAL PLAN ---SHOW SMOKE DETECTORS AND CO2 DETECTORS E). SUBMITTAL INCLUDES SCREENED PORCH, DO NOT ENCROACH UPON SIDE YARD SETBACK F). SHOW UTILITY PLACEMENT ON ALL PLOT PLANS
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
GRIFFIN PARC #01
|
OWNER | GILBERT M HOWARD | (972)466-1120 | | P.O. BOX 112922 | CARROLLTON, TX 75011 |
APPLICANT | GILBERT M HOWARD | (972)466-1120 | | P.O. BOX 112922 | CARROLLTON, TX 75011 |
CONTRACTOR | GILBERT M HOWARD | (972)466-1120 | | P.O. BOX 112922 | CARROLLTON, TX 75011 |
GEN. CONTR. | GILBERT M HOWARD | (972)466-1120 | | P.O. BOX 112922 | CARROLLTON, TX 75011 |
IRRIGATION | STEVE'S IRRIGATION | (972)849-2485 | | P.O. BOX 733 | LITTLE ELM, TX 75068 |
MECH. CTR. | HOUK AIR CONDITIONING X-04/05 | (817)265-1191 | | 128 FAIRVIEW | ARLINGTON, TX 76010 |
PLUM. CONT. | ELITE PLUMBING | (972)466-1120 | | P.O. BOX 112922 | CARROLLTTON, TX 75011 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/27/2005
| | 6/27/2005 | |
More Info
|
There are currently no reviews on this record.