Notes:
2409 A/C, 3226 SF, SF / 1 STORY
12/18/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
42. PROVIDE SOIL MOISTURE TREATMENT DOCUMENTATION PRIOR TO STARTING CONSTRUCTION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
A). FUTURE SUBMITTALS-- BREAKDOWN SQ.FOOTAGE; A/C SPACE COVERED PATIOS AND PORCHES AND GARAGE B). 2'&10' RULE WILL APPLY AT CHIMNEY C). NEED TO PICK UP CONTRACTORS GUIDELINE AT CITY OF FRISCO D). ELECTRICAL PLAN ---SHOW SMOKE DETECTORS AND CO2 DETECTORS E). SUBMITTAL INCLUDES SCREENED PORCH, DO NOT ENCROACH UPON SIDE YARD SETBACK F). SHOW UTILITY PLACEMENT ON ALL PLOT PLANS