Permit Info
Short Description:
1 BF -- see BF07-0341 -- CENTENNIAL CLEANERS
Notes:
1- CONTINGENT UPON COMPLIANCE WITH BLDG CODE & LOCAL REQUIREMENTS, PERTINENT LEGISLATIONS AND REVIEW COMMENTS.
2- PROVIDE 2 HR DEMISING WALL (WITH SOUND INSULATION) AS REQ'D FOR SEPARATION OF CLEANERS FACILITY FROM ADJACENT TENANTS.
3- THE STOREFRONT END OF RATED WALLS MUST HAVE VALID FIRE/SMOKE CONNECTION TO THE STOREFRONT'S MULLION (NOT TO GLASS) TO MEET INSPECTOR'S APPROVAL.
4- FRONT ENTRANCE PUBLIC WAITING AREA IS TO BE LIMITED TO 210 SQ. FEET AND SO IDENTIFIED BY SERVICE COUNTER. ANY EXTENSION OF THAT SPACE, OR DIFFERENT USE OF OTHER SPACES FROM WHAT PERMITTED, COULD INCREASE THE TOTAL OCCUPANCY LOAD ABOVE 15 PEOPLE AND, IN TAL CASE, REQUIRING THE ADDITION OF A SECOND TOILET AS PER CODE.
5- PENDING SUBMITTAL OF UPDATED (& GRAPHICALLY CORRECT) ARCHITECTURAL FLOOR PLAN SHOWING PROPOSED CHANGES FROM PREVIOUSLY PERMITTED SHELL STOREFRONTS (WITH ALL MULLIONS EXACTLY LOCATED) AND RELATED CONSTRUCTION DETAILS.
6- PENDING SUBMITTAL OF TDLR REGISTRATION NUMBER FOR TAS REVIEW AS REQ'D TO VALIDATE THIS PERMIT.
7- ALL CONSTRUCTION TO BE TYPE II-B (NON-COMBUSTIBLE MATERIALS) AS REQ'D.
8- NO GAS-FIRED APPLIANCES ALLOWED IN THE WORK AREA UNLESS SEPARATED BY 2 HR ENCLOSURE & APPROVED BY FIRE MARSHAL.
9- EXTERIOR WALLS TO BE BATT INSULATED R-13 (AS PER SHELL PERMIT) AND FINISHED WITH 5/8" GYP. B'D AS REQ'D.
10-MECH'L ENGR TO VERIFY IF ADEQUATE VENTILATION/EXHAUST SYSTEMS ARE PROVIDED THROUGHOUT AS REQ'D.
11-SUBJECT TO M.E.P. REVIEWS, FIRE MARSHAL AND FIELD INSPECTIONS.
(1/24/2005 08:33 MBW) ALL CONTRACTORS MUST VALIDATE AND OBTAIN CURRENT REGISTRATION WITH THE CITY PRIOR TO START OF PROJECT.
1 BF -- see BF07-0341 -- CENTENNIAL CLEANERS
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
PLANTATION ADDITION (CFR)
|
| BF TESTER | JOSHUA LEMONS | (972)298-2772 | | 3730 GUS THOMASSON | MESQUITE, TX 75150 |
| OWNER | CENTENNIAL CLEANERS | (214)705-0250 | | 6449 COIT RD. | FRISCO, TX 75034 |
| MAIL TO | CENTENNIAL CLEANERS | (214)705-0250 | | 6449 COIT RD. | FRISCO, TX 75034 |
| APPLICANT | SCHON BUILDING X-03/03 | (214)292-0035 | | 10875 SHADY TRAIL | DALLAS, TX 75220 |
| CONTRACTOR | SCHON BUILDING X-03/03 | (214)292-0035 | | 10875 SHADY TRAIL | DALLAS, TX 75220 |
| ELECT. CTR. | DGO ELECTRIC X-11/05 | (972)998-2355 | | 2506 FRUITLAND | FARMERS BRANCH, TX 75234 |
| GEN. CONTR. | SCHON BUILDING X-03/03 | (214)292-0035 | | 10875 SHADY TRAIL | DALLAS, TX 75220 |
| MECH. CTR. | CITI-AIR SERVICE X-6/2005 | (972)303-5051 | | 3614 BOBTOWN RD APT 108 | GARLAND, TX 75043 |
| PLUM. CONT. | PETE & SONS-NOT REGISTERED | ()- | | | |
| Total Fees |
|
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.