Short Description:
537 SQ FT , SADD / PATIO COVER, BALCONY, FIREPLACE & KITCHEN
Notes:
537 SQ FT , SADD / PATIO COVER, BALCONY, FIREPLACE & KITCHEN
5/12/2007 12:00:00 AM
537 SQ FT , SADD / PATIO COVER, BALCONY, 1/2 BATH, OUTDOOR FIREPLACE & KITCHEN W/ BBQ GRILL, SINK, REFIGERATOR & ICE MAKER
REPLACE STONE/BRICK:
* ALL WORK PERFORMED MUST MEET THE 2003 IRC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE.
SUBJECT TO FIELD INSPECTION APPROVAL. CALL (972) 292-5386 FOR INSPECTION. **
* WILL REQUIRE INSPECTIONS OF... LENTIL SUPPORT, WEEP HOLES, FLASHING, AND BRICK TIES.
OUTDOOR KITCHEN SINK:
* OUTDOOR KITCHEN SINK MUST DRAIN TO THE SANITARY SEWER DRAIN THROUGH TRAPPED MEANS.
OUTDOOR FIREPLACE:
* ALL WORK PERFORMED MUST MEET THE 2003 IRC STANDARDS.
SUBJECT TO FIELD INSPECTION APPROVAL.
CALL (972) 292-5386 FOR INSPECTION.
* FIREPLACE MUST BE 100% MASONRY.
* VENTING AND FLUE MUST MEET MANUFACTURERS SPECIFICATIONS.
* MUST MAINTAIN TEN FOOT CLEARANCE FROM ALL COMBUSTABLE ITEMS.
* CHIMNEY MUST MAINTAIN A MINIMUM OF 2' IN CLEARANCE IN HEIGHT WITHIN A 10' RADIUS OF CHIMNEY.
R1001-6 THE 2' & 10' RULE WILL APPLY FOR FIREPLACE
(5/23/2007 13:06 JM)
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
08. BEAMS=10"W X 24"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.