Notes:
3/9/2018 1:11:00 PM
PERMIT IS FOR ONE 20X40 TENT AT THE STONEBROOK SQUARE COMMERCIAL PROPERTY FOR A SUMMER BASH EVENT.
PERMIT DOES NOT AUTHORIZE EVENT OR MISC. STRUCTURES.
MAY NOT OBSTRUCT FIRE LANE, HANDICAP PARKING & ACCESSIBILITY, MANDATORY PARKING, STREET TRAFFIC, RIGHT OF WAY, OR VISIBILITY(VAM).
MAY MOUNT ONE BANNER NOT TO EXCEED 48 SQ FT TO TENT WITHOUT ADDITIONAL PERMIT.
ALL AIRBORNE DEVICES (FLAGS, PENNANTS, BALLOONS, ETC.) ARE PROHIBITIED PER ORDINANCE 16-03-25.
SMOKING PROHIBITTED IN ENCLOSED SPACES. REGULATED PER ORDINANCE #06-11-018.
ANY/ALL FOOD PROVISIONS MUST BE APPROVED BY THE HEALTH AND FOOD SAFETY DEPARTMENT UNDER SEPERATE TEMPORARY HEALTH PERMIT.
SUBJECT TO APPROVAL BY FIRE MARSHAL AND POLICE DEPARTMENT.
PERMIT VALID 05/05/2018
CALL FIRE MARSHAL OFFICE FOR TENT INSPECTION AT LEAST ONE WORKING DAY IN ADVANCE AT 972-292-6328.
4/9/2018 9:02:57 AM
FIRE MARSHAL OFFICE COMMENTS:
JESSE ZITO
FIRE TENT/SPCL EVENT
1. An inspection from the Fire Marshal’s Office and the Building Department is required prior to occupancy. Please call the Fire Marshal’s Office Inspection Line 972-292-6328, once the tent has been installed.
2. Tents cannot obstruct the fire lane or vehicular traffic flow.
3. Need to post the occupant load sign for each tent:
• 40’x 20’ Tent = 53 People Max.
4. Minimum required exiting:
• All tents shall have a minimum of (3) exits at 72 inches wide.
5. The exits shall be spaced at equal intervals around the perimeter of the tent. Proper exiting width shall be maintained between the tent and other structures.
6. Aisle widths and exits shall be maintained per the 2012 IFC and IBC.
7. If sides are installed, exit signs shall be placed over the required exits. Exit signs must be illuminated at all times.
8. Need to provide (2) 2A10BC “ABC” fire extinguishers for each the tent.
• The fire extinguisher must have a current inspection tag.
• The fire extinguisher shall be placed in the path of egress and mounted so that its top is not more than 5 feet above the floor.
9. Need to provide and post a “NO SMOKING” sign on the interior of each tent.
10. Generators must be a minimum of 20 feet away from the tent structures and shall be isolated from contact with the public by fencing or other approved method.
11. Smoking, open flames or cooking is not permitted under tent structures.
12. Must meet all the minimum requirements of the International Fire Code and Building Code.
13. Additional requirements may be required when a site inspection is conducted.