Notes:
8/10/2021 1:44:04 PM
03. WATER VELOCITY SYSTEMS SHALL BE DESIGNED TO PREVENT WATER VELOCITY IN SUCTION PIPING FROM EXCEEDING 6 FPS (FEET PER SECOND), AND PRESSURE PIPING FROM EXCEEDING 10 FPS. WATER VELOCITY THROUGH SUCTION GRATES/COVERS SHALL NOT EXCEED 1.5 FPS WITH ONE GRATE 100% BLOCKED, OR THE ASME/ANSI A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED GPM (GALLONS PER MINUTE) FLOW RATE WITH ONE COVER 100% BLOCKED.
06. CONTRACTOR SHALL PROVIDE VAPOR RETARDANT POOL COVER FOR USE WHEN HEATING EQUIPMENT IS UTILIZED.
07. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
08. CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD.
09. OPTIONS NOT PART OF POOL STRUCTURE AS WELL AS PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT
10. EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE LESS THAN 6 HRS.
12. CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
14. STRUCTURES EQUAL AND GREATER THAN 36" IN HEIGHT MUST BE ENGINEERED.
15. PLEASE NOTE: THIS PLACARD DOES NOT INCLUDE ALL REQUIREMENTS.
16. NO ELECTRICAL CONDUCTORS SMALLER THAN NUMBER 12 COPPER ALLOWED.
17. POOL BENCH AND SEATING AREAS MUST BE CONSTRUCTED TO PREVENT ENTRAPMENT OR INJURY TO USERS. NO PROTRUSIONS, EXTENSIONS OR MEANS OF ENTANGLEMENT OR OTHER OBSTRUCTION THAT MAY CAUSE ENTRAPMENT OR INJURY ARE ALLOWED.
19. ALL AUTO FILL LINES MUST HAVE RPZ.
TO SCHEDULE INSPECTIONS, SEND EMAIL TO BINSPECTIONVM@FRISCOTEXAS.GOV WITH THE INSPECTION REQUESTED, LOCATION, DAY, CONTRACTOR, AND REQUESTORS RELATION TO THE PERMIT. INSPECTION UPDATES CAN BE VIEWED THROUGH ETRAKIT BY SEARCHING FOR THE PROJECT PERMIT NUMBER. CALL (972)292-5317 FOR QUESTIONS.