Notes:
7/12/2021 2:24:53 PM
000 -- POOLS AND SPAS MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH NSPI STANDARDS AND THE CURRENT IRC AS ADOPTED AND AMENDED. -- DUAL HYDRAULICALLY BALANCED MAIN DRAINS REQUIRED ON EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALL OR FEATURES. MAIN DRAIN COVERS/GRATES MUST BE ANSI/ASME A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED AND MUST HAVE MINIMUM 3 FT SEPARATION BETWEEN INSIDE EDGES OF COVER/GRATE TO COVER/GRATE. ALL SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION. -- WATER VELOCITY SYSTEMS SHALL BE DESIGNED TO PREVENT WATER VELOCITY IN SUCTION PIPING FROM EXCEEDING 6 FPS (FEET PER SECOND), AND PRESSURE PIPING FROM EXCEEDING 10 FPS. WATER VELOCITY THROUGH SUCTION GRATES/COVERS SHALL NOT EXCEED 1.5 FPS WITH ONE GRATE 100% BLOCKED, OR THE ASME/ANSI A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED GPM (GALLONS PER MINUTE) FLOW RATE WITH ONE COVER 100% BLOCKED. -- DIVING BOARDS AND SLIDES AND THEIR ASSOCIATED ENVELOPES MUST MEET NATIONAL STANDARDS (NSPI OR CPSC) AND BE INSTALLED PER MANUFACTURER INSTRUCTIONS. STEPS AND HANDRAILS FOR STRUCTURES SUCH AS SLIDES AND BRIDGES MUST COMPLY WITH BUILDING CODES. -- GAS VENT TO TERMINATE MINIMUM 5' HORIZONTAL FROM OPENABLE WINDOW OR 3' MINIMUM ABOVE. -- WINDOWS LESS THAN 5' TO WATER MUST BE TEMPERED/SAFETY GLAZED TO CODE. -- CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION. -- CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD. -- OPTIONS NOT PART OF POOL STRUCTURE AS WELL AS PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT. -- EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE LESS THAN 6 HRS. -- BACKWASH LINE MUST BE INSTALLED AT TIME OF TRAP INSPECTION TO INSURE PROPER AIR GAP. -- CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
001 -- POOL CLEANER SUCTION LINES (OTHER THAN SKIMMER USE) ARE NOT ALLOWED UNLESS INSTALLED WITH AN APPROVED COVER THAT SELF CLOSES AND LATCHES AND CANNOT BE OPENED WITHOUT THE USE OF A TOOL. -- STRUCTURES OVER 36 IN HEIGHT MAY REQUIRE AN ENGINEERED DESIGN IF DEEMED A SPECIAL CONDITION. -- PLEASE NOTE: THIS PLACARD DOES NOT INCLUDE ALL REQUIREMENTS. -- NO ELECTRICAL CONDUCTORS SMALLER THAN NUMBER 12 COPPER ALLOWED. -- POOL BENCH AND SEATING AREAS MUST BE CONSTRUCTED TO PREVENT ENTRAPMENT OR INJURY TO USERS. NO PROTRUSIONS, EXTENSIONS OR MEANS OF ENTANGLEMENT OR OTHER OBSTRUCTION THAT MAY CAUSE ENTRAPMENT OR INJURY ARE ALLOWED. -- EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALLS AND FEATURES MUST HAVE AN APPROVED ASME/ANSI A112.19.17 SVRS AND BE INSTALLED BY A CERTIFIED INSTALLER TRAINED AND CERTIFIED BY THE MANUFACTURER OF THE DEVICE. THE CERTIFIED INSTALLER SHALL ENSURE THE SVRS DEVICE IS INSTALLED PROPERLY INCLUDING A BALL VALVE ON EACH SYSTEM TO ALLOW THE DEVICE TO BE TESTED. THE CERTIFIED INSTALLER SHALL PROVIDE A SIGNED DOCUMENT CERTIFYING THE APPROVED INSTALLATION OF THE DEVICE AND BALL VALVE. -- ALL AUTO FILL LINES MUST HAVE RPZ. -- COPING, HANDHOLDS, ROCKS, STONES, OR OTHER MATERIALS THAT ARE PART OF WATER OR OTHER FEATURES MAY NOT PROTRUDE MORE THAN 2" PAST THE POOL BEAM. -- DISTANCE FROM NEAREST FOUNDATION (1:1 RATIO) DEPTH/DISTANCE FROM BACK TO BEAM TO FOUNDATION OR AN ENGINEER'S LETTER REQUIRED. -- POOLS GREATER THAN 5FT. MUST HAVE MEANS OF EXIT OUT OF DEEP END PER ANSI/NSPI. -- NO PART OF POOL BEAM OR DECK MAY BE BUILT IN ANY EASEMENT. ANYTHING PLACED IN AN EASEMENT IS SUBJECT TO REMOVAL OR RELOCATION AT HOMEOWNER EXPENSE. -- CONTRACTOR SHALL PROVIDE VAPOR RETARDANT POOL COVER FOR USE WHEN HEATING EQUIPMENT IS UTILIZED.