Permit Info
Short Description:
POOL AND SPA
Expiration Date:
7/20/2021
Notes:
1/19/2021 2:56:09 PM
*******ENGINEER LETTER ON FILE FOR RAISED BEAM OVER 36" IN HEIGHT.
THE RECOMMENDATIONS CONTAINED IN THE ENGINEER LEETER SHOULD BE FOLLOWED AS STATED. ANY DEVIATION FROM THE ENGINEER'S RECOMMENDATIONS SHOULD BE APPROVED BY THE PERMITTING AUTHORITY PRIOR TO BEING IMPLEMENTED. SHOULD SLOUGHING OR ANY OTHER ISSUES OCCUR, THE ENGINEER SHOULD BE CONTACTED IMMEDIATELY.
000 -- POOLS AND SPAS MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH NSPI STANDARDS AND THE CURRENT IRC AS ADOPTED AND AMENDED. -- DUAL HYDRAULICALLY BALANCED MAIN DRAINS REQUIRED ON EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALL OR FEATURES. MAIN DRAIN COVERS/GRATES MUST BE ANSI/ASME A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED AND MUST HAVE MINIMUM 3 FT SEPARATION BETWEEN INSIDE EDGES OF COVER/GRATE TO COVER/GRATE. ALL SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION. -- WATER VELOCITY SYSTEMS SHALL BE DESIGNED TO PREVENT WATER VELOCITY IN SUCTION PIPING FROM EXCEEDING 6 FPS (FEET PER SECOND), AND PRESSURE PIPING FROM EXCEEDING 10 FPS. WATER VELOCITY THROUGH SUCTION GRATES/COVERS SHALL NOT EXCEED 1.5 FPS WITH ONE GRATE 100% BLOCKED, OR THE ASME/ANSI A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED GPM (GALLONS PER MINUTE) FLOW RATE WITH ONE COVER 100% BLOCKED. -- DIVING BOARDS AND SLIDES AND THEIR ASSOCIATED ENVELOPES MUST MEET NATIONAL STANDARDS (NSPI OR CPSC) AND BE INSTALLED PER MANUFACTURER INSTRUCTIONS. STEPS AND HANDRAILS FOR STRUCTURES SUCH AS SLIDES AND BRIDGES MUST COMPLY WITH BUILDING CODES. -- GAS VENT TO TERMINATE MINIMUM 5' HORIZONTAL FROM OPENABLE WINDOW OR 3' MINIMUM ABOVE. -- WINDOWS LESS THAN 5' TO WATER MUST BE TEMPERED/SAFETY GLAZED TO CODE. -- CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION. -- CONTRACTORS: INFORM HOMEOWNER OF NECESSITY FOR INSPECTORS TO ACCESS BACKYARD. -- OPTIONS NOT PART OF POOL STRUCTURE AS WELL AS PATIO COVERS, ARBORS, OUTDOOR KITCHENS, BBQ GRILLS, FIRE PLACES/PITS AND FENCES REQUIRE A SEPARATE PERMIT. -- EQUIPMENT MUST BE 3' MINIMUM FROM PROPERTY LINE. TURNOVER RATE TO BE LESS THAN 6 HRS. -- BACKWASH LINE MUST BE INSTALLED AT TIME OF TRAP INSPECTION TO INSURE PROPER AIR GAP. -- CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PHASE 6B
|
| OWNER | BOOMSTRA, TREVOR & CHIEN-HUI | ()- | | | FRISCO, TX 75033-6206 |
| APPLICANT | POOL ENVIRONMENTS | (972)985-1576 | schedulingdesk@poolenvironments.com | 1006 20TH STREET | PLANO, TX 75074 |
| ELECT. CTR. | AQUA TECH ELECTRIC | (972)243-2162 | ron.aquatechelectric@hotmail.com | 11252 GOODNIGHT LN STE 900 | DALLAS, TX 75229 |
| POOL CONTRAC | POOL ENVIRONMENTS | (972)985-1576 | schedulingdesk@poolenvironments.com | 1006 20TH STREET | PLANO, TX 75074 |
| PLUMBING | SOUTHWESTERN PLUMBING CO. | (817)522-8995 | southwesternplumbing@gmail.com | 13391 GEORGE FOSTER RD | PONDER, TX 76259 |
|
| PERMIT CANCELLED |
($244.00)
|
3/9/2021
|
| CREDIT CARD FEE |
$6.10
|
1/21/2021
|
| IN-GROUND POOL BUILDING PERMIT FEE |
$200.00
|
1/21/2021
|
| POOL FEE |
$10.00
|
1/21/2021
|
| POOL PLUMBING FEE |
$20.00
|
1/21/2021
|
| SPA |
$75.00
|
1/21/2021
|
| Total Fees |
|
Charged: $67.10
Balance Due: $0.00
|
There are currently no inspections on this record.
|
| POOL REVIEW | RYAN KUHLMAN | DENIED | 12/4/2020 | 12/8/2020 | 12/18/2020 |
More Info
|
| POOL REVIEW | TINA MOORE | APPROVED | 1/19/2021 | 1/19/2021 | |
More Info
|
| INITIAL REVIEW | KELLY EVANS | | | | |
More Info
|