Notes:
10 SQ FT / FOUNTAIN / WATER FEATURE
3/9/2012 12:00:00 AM
POOL REVIEW NOTES
REVIEW TYPE: ROBERT THOMAS REVIEWER: ROBERT THOMAS
0.1 ALL BUILDING INSPECTIONS APPLY TO FOUNTAINS.
0.2 LIGHTS MUST BE PROTECTEDBY GFCI.
0.3 DICONNECT AND CONTROLER MUST BE WITH IN SITE OF FOUNTAINS.
0.4 APPROVED PERMIT SET OF PLANS MUST BE ON SITE.
0.5 MAIN DRAIN GATES MUST BE ASME/ANSI A 112.19.8- 2007 OR SUCCESSOR STANDARDAPPROVED, BE HYDRAULICALLY BALANCED, AND MUST HAVE MINIMUM 3' SEPERATION FROM INSIDE EDGE OF GRATES TO GRATES.
0.6 SUCTION SYSTEMS TO BE PLUMBED ACCORDING TO ENGINEERED PLANS AND DRAWINGS.
0.7 SUCTION SYSTEMS MAY NOT EXCEED APPROVED FLOW RATES( APPROVED GPM OR 1.5 FPS) OF COVERS/GRATES WHEN BOTH PUMPS RINNING AND WITH ONE COVER / GRATE 100% BLOCKED.
0.8 FOUNTAIN DEPTH CANNOT EXCEED 18".
0.9 CIRCULATION SYSTEMS CONSISTING OF PUMPS, PIPE, FILTERS, AND AUTOMATED CHLORINATORS SHALL BE PROVIDED AND DESIGNED TO MAINTAIN A HEALTH FOUNTAIN ENVIRONMENT.