Notes:
ENSURE NO ENTRAPMENT HAZARDS.
WF -3.20: DUAL HYDRAULICALLY BALANCED MAIN DRAINS REQUIRED ON EACH SUCTION SYSTEM INCLUDING CIRCULATION, BOOSTERS, WATER FALL OR FEATURES. MAIN DRAIN COVERS/GRATES MUST BE ANSI/ASME A112.19.8 - 2007 OR SUCCESSOR STANDARD APPROVED AND MUST HAVE MINIMUM 3 FT SEPARATION BETWEEN INSIDE EDGES OF COVER/GRATE TO COVER/GRATE. IF FIELD BUILT SUMPS AND CUSTOM COVERS (GRANITE), SUBMIT PRE-AND POST- CONTRUCTION ENGINEER LETTERS. SUCTION SUMPS MUST BE INSTALLED PRIOR TO B-STEEL INSPECTION.
12. CONTRACTOR REQUIRED TO COMPLY WITH ALL ORDINANCES. DOCUMENTATION AVAILABLE TO ASSIST YOU AT CITY OFFICES.
1.MINIMUM #12 COPPER CONDUCTORS PERMITTED EXCEPT FOR CONTROLS. LIGHT COMCHECK CALCULATIONS MUST MATCH PLANS.
2.PULL EQUIPMENT GROUNDS IN ALL RACEWAYS.
3. ALL EXTERIOR LIGHTING SHALL COMPLY WITH THE COMPREHENSIVE ZONING ORDINANCE ARTICLE IV SECTION 6.
4. ALL ELECTRICAL INSTALLATIONS WILL BE SUBJECT TO FIELD INSPECTIONS AND INSPECTOR APPROVALS.
5. ALL CONDUCTORS MUST TERMINATE IN DEVICES THAT HAVE BEEN PROPERLY TIGHTENED TO MANUFACTURERS’ TORQUE SPECIFICATIONS USING THE PROPER TORQUE TOOL.
6. LEGIBLE PANEL SCHEDULE SHALL BE PROVIDED AT ALL PANEL LOCATIONS.
7. ELECTRICAL WILL BE DESIGNED AND INSTALLED PER THE 2005 NATIONAL ELECTRICAL CODE WITH LOCAL AMENDMENTS STATED IN CITY OF FRISCO ORDINANCE.
8. GROUNDING AND BONDING SHALL COMPLY WITH ARTICLE 250 2005 NEC.
1. RPZ REQUIRED AT WATER SUPPLY FOR FOUNTIAN EQUIPMENT.
FOREST PARK WATER FEATURE-OUTDOOR