Notes:
FOUNTAIN / PARKVIEW SENIOR RESIDENCE
5/7/2007 12:00:00 AM
- PROVIDE DEPTH OF FOUNTAIN (CANNOT EXCEED 18 " DEPTH).
- PROVIDE PLUMBING DETAILS INCLUDING PUMP(S) AND SUCTION OUTLETS (COVERS/GRATES),
- MINIMUM DUAL MAIN DRAINS OR GRATES REQUIRED FOR EACH SUCTION PUMP. APPROVED DRAIN COVERS OR GRATES (ASME/ANSI A112.19.8M COVERS NOT HAVING WATER FLOW THAT EXCEEDS THE APPROVED MAXIMUM GALLONS PER MINUTE, GRATES THAT ARE 12 X 12 OR LARGER MAY BE USED BUT CANNOT EXCEED 1.5 FPS THROUGH REMAINING GRATE(S)/DRAINS(S) WITH ONE GRATE/DRAIN BLOCKED 100%.). COVERS AND GRATES MUST HAVE MINIMUM OF 3 FT. SEPARATION BETWEEN INSIDE EDGES OF COVER TO COVER OR GRATE TO GRATE.
- MINIMUM OF FOUR (4) TILE SIGNS PLACED AROUND COPING OF FOUNTAIN, STATING "FOUNTAIN, NO SWIMMING, NO DIVING" (4" LETTER HEIGHT)
- PROVIDE ENGINEERS LETTER OR PLAN ADDENDUM REGARDING SUCTION SYSTEM FLOW NOT TO EXCEED APPROVED WATER FLOW THROUGH REMAINING COVERS/GRATES WITH ONE 100% BLOCKED.