Notes:
POOL AND SPA
12/30/2005 12:00:00 AM
1. DUAL MAIN DRAINS REQUIRED WITH MINIMUM SEPERATION OF 3 FT BETWEEN INSIDE EDGES OF DRAIN COVERS.
2. DIVING BOARD AND ENVELOPE TO MEET NSPI STANDARDS.
3. TURNOVER RATE TO BE LESS THAN 6 HOURS.
4. GAS VENT TO BE 5 FT AWAY FROM ANY OPENABLE WINDOW.
5. WINDOWS WITHIN 36" OF WALKWAY OR <5' TO WATER MUST BE SAFETY GLAZED TO CODE.
6. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
7. CONTRACTORS: IT IS YOUR RESPONSIBILITY TO INFORM THE HOMEOWNER OF THE NECESSITY OF INSPECTORS TO GAIN ACCESS TO THE BACKYARD.
8. ARBORS, PATIO COVERS, OUTDOOR KITCHENS, BBQ GRILLS, AND FIRE PITS MUST BE PERMITTED SEPARATELY.
9. SLIDE MUST MEET CPSC STANDARDS, AND HAVE ENTRY OF >5' WATER. 10. STRUCTURES > 36" IN HEIGHT REQUIRE ENGINEERS LETTER.
(2/7/2006 10:02 SEL) RECEIVED LETTER FROM PLUMB. CONTR. "SOUTHWESTERN PLUMBING. THEY ARE NOT DOING PLUMB. ON THIS PERMIT. REMOVED PLUMBING PER LETTER.