Notes:
POOL, SPA & FIRE PIT
12/29/2005 12:00:00 AM
1. DUAL MAIN DRAINS REQUIRED WITH MINIMUM SEPERATION OF 3 FT BETWEEN INSIDE EDGES OF DRAIN COVERS.
2. DIVING BOARD AND ENVELOPE TO MEET NSPI STANDARDS.
3. TURNOVER RATE TO BE LESS THAN 6 HOURS.
4. GAS VENT TO BE 5 FT AWAY FROM ANY OPENABLE WINDOW.
5. WINDOWS WITHIN 36" OF WALKWAY OR <5' TO WATER MUST BE SAFETY GLAZED TO CODE.
6. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
7. CONTRACTORS: IT IS YOUR RESPONSIBILITY TO INFORM THE HOMEOWNER OF THE NECESSITY OF INSPECTORS TO GAIN ACCESS TO THE BACKYARD.
(12/29/2005 18:23 JKT)
BBQ GRILL, OUTDOOR KITCHEN, PATIO COVER, ARBOR MUST BE PERMITTED SEPARATELY. STRUCTURES OVER 36" IN HEIGHT REQUIRE ENGINEER LETTER. ACCENT BOULDERS ENCROACHING WATERS EDGE CANNOT EXCEED 18" IN HEIGHT ABOVE WATER LINE.
(12/30/2005 09:12 JKT)
FIRE PIT APPROVED PER SC.