POOL AND SPA
12/12/2005 12:00:00 AM
(12/12/2005 15:14 JS)
1. DUAL MAIN DRAINS REQUIRED WITH MINIMUM SEPERATION OF 3 FT BETWEEN INSIDE EDGES OF DRAIN COVERS.
2. DIVING BOARD AND ENVELOPE TO MEET NSPI STANDARDS.
3. TURNOVER RATE TO BE LESS THAN 6 HOURS.
4. GAS VENT TO BE 5 FT AWAY FROM ANY OPENABLE WINDOW.
5. WINDOWS WITHIN 36" OF WALKWAY OR <5' TO WATER MUST BE SAFETY GLAZED TO CODE.
6. CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
7. CONTRACTORS: IT IS YOUR RESPONSIBILITY TO INFORM THE HOMEOWNER OF THE NECESSITY OF INSPECTORS TO GAIN ACCESS TO THE BACKYARD.
(12/12/2005 15:14 JS)
DECKING OK BY SC TO ENCROACH EASEMENT WITH ACKNOWLEDGMENT FROM OWNER THAT THEY ARE RESPONSIBLE TO REPLACE IF DAMAGED DUE TO EASEMENT MAINTENANCE. PATIO COVER, ARBOR, OUTDOOR KITCHEN, GRILL, FIREPLACE AND PIT REQUIRE SEPARATE PERMIT.