Notes:
POOL AND SPA
3/24/2005 12:00:00 AM
DUAL MAIN DRAINS REQUIRED
TURNOVER RATE TO BE LESS THAN 6 HOURS
POOL EQUIPMENT TO BE 5 FEET AWAY FROM ANY OPENABLE WINDOW
BOARD TO MEET NSPI STANDARDS
CONTRACTORS: IT IS YOUR RESPONSIBILITY TO INFORM THE HOMEOWNER OF THE NECESSITY OF INSPECTORS TO GAIN ACCESS TO THE BACKYARD.
CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
(3/24/2005 08:41 JKT)PLEASE INDICATE 2 MAIN DRAINS IN THE SPA AREA. INDICATE TURNOVER RATE ON ALL FUTURE PLAN SUBMITTALS. FOUNTAIN MUST BE PERMITTED SEPERATELY. GREATER THAN 5' FROM WATER OR GROUND AND BONDED BARRIER REQUIRED. LESS THAN 5' TO WATERS EDGE OR WITHIN 36" OF A WALKWAY AROUND POOL. GROUND ALL METALS WITHIN 5' AS WELL. WINDOWS WITHIN 36" OF WALKWAY OR LESS THAN 5' TO WATER MUST BE SAFETY GLAZED.