Notes:
BELLA CASA AMENITY CENTER POOL
2/25/2005 12:00:00 AM
(2/25/2005 11:55 JS)MAX. BATHER LOAD = 160 PP. TELEPHONE SHALL BE LOCATED TO COMPLY WITH CODE. FOR LOCKED GATES AND FENCE >4'4'', LOCATE PHONE ON OUTSIDE OF ENCLOSURE WITHIN 50 FT. OF WATER. CALL FOR OTHER SPECIFICATIONS. SEE ATTACHED REQUIREMENTS.(1/20/2005 14:40 JS) (1/20/2005 13:59 JS)
DUAL MAIN DRAINS REQUIRED
TURNOVER RATE TO BE LESS THAN 6 HOURS
POOL EQUIPMENT TO BE 5 FEET AWAY FROM ANY OPENABLE WINDOW
BOARD TO MEET NSPI STANDARDS
CONTRACTORS: IT IS YOUR RESPONSIBILITY TO INFORM THE HOMEOWNER OF THE NECESSITY OF INSPECTORS TO GAIN ACCESS TO THE BACKYARD.
CERTIFICATION OF POOL PROTECTION DEVICE INSTALLATION TO BE SIGNED AND ON SITE AT PRE-PLASTER INSPECTION.
(1/20/2005 14:00 JS)SEE ATTACHED SHEET FOR REQUIRED GUIDELINES. 2'' TILE BAND REQUIRED AT 5'0'' MARK SHALL BE INSTALLED. MAX. BATHER LOAD = 200. STEPS: MAX RISE = 10'', MIN. RUN= 12'', MIN. WIDTH 20''. LADDERS SHALL MEET ALL POOL REQUIREMENTS FOR EXITING. PROVIDE ALL GAUGES. PROVIDE OBSERVABLE WASTE DISCHARGE GLASS. LOCATE TELEPHONE PER MIN. STANDARDS AND PER LOCAL CODE. ENSURE ENCLOSURE MEETS POOL CODE - FAX DESIGN FOR APPROVAL 972.335.5579.
(2/18/2005 10:06 MBW) CORRECTED ADDRESS FROM 6831 FIRENZE TO 5705 GROSSETO.