Notes:
11/9/2018 4:53:15 PM
MIKE TROTTER I-3348
PLUMBING REVIEW
450. ALL WORK PERFORMED MUST MEET THE 2015 IRC, 2015 IBC AND 2015 IPC STANDARDS AND ABIDE BY THE CITY OF FRISCO COMPREHENSIVE ZONING ORDINANCE, AND ALL OTHER CITY ORDINANCES.
451. SUBJECT TO FIELD INSPECTION APPROVAL-CALL (972) 292-5386 FOR INSPECTION
452. BELOW GRADE WASTE TIE-INS, SOLVENT JOINT OR MISSION TYPE S.S. BANDS.
453. BELOW GRADE PIPING TO BE BEDDED WITH SAND.
454. TRENCHES TO BE COPACTED AT BACKFILL.
457. COMPRESSION TYPE MECHANICAL JOINTS ARE NOT PERMITTED UNDERGROUND
456. FLOOR AND HUB DRAINS INSTALLED WITH TRAP PRIMER.
459. ALL GAS PIPING EXPOSED TO THE ELEMENTS MUST BE PROTECTED FROM CORROSIONIN AN APPROVED MANNER
460. ALL GAS REGULATORS MUST BE INSTALLED AFTER SEDIMENT TRAP AS REQUIRED BY CODE
461. A GASLINE PRESSURE TEST IS REQUIRED WHEN ADDING A GAS APPLIANCE
462.BACK WATER VALVE MUST BE ACCESSIBLE
11/8/2018 2:35:46 PM