Notes:
IRRIGATION
9/6/2017 12:00:00 AM
1. ALL REQUIRED TREES MUST BE BAGGED OR BUBBLED ON THEIR OWN ZONE. HEADS IN AREAS LESS THAN TEN FEET MUST BE ONE OF TWO ACCEPTED HEADS. ALL IRRIGATION IS SUBJECT TO FIELD INSPECTIONS. FRONT, BACK AND BOTH SIDE MICRO ZONES MUST HAVE THEIR OWN ZONES. PLANS SHOWING ZONE CALCULATIONS MUST BE WITH THE PERMIT AT FINAL INSPECTION.
2. ALL COMMERCIAL BACKFLOW LOCATIONS MUST BE IDENTIFIED BY USING GPS AND WRITTEN ON THE BACKFLOW REPORT SUBMITTED TO THE CITY.
3. ALL SENSORS MUST BE IN FULL SUN AND ABOVE ANY OVERHANG.
4. ALL SOD AND LANDSCAPE MUST BE INSTALLED.
5. AN APPROVED ET CONTROLLER AND SENSOR IS REQUIRED ON ALL NEW INSTALLATIONS.
6. AREAS WIDER THAN 8' MUST HAVE HEADS SPRAYING BACK TO ACHIEVE HEAD TO HEAD COVERAGE.
7. MUST HAVE ZONE CHART AT CONTROLLER UPON INSPECTIONS.
8. PRESSURE REGULATOR WITH MINIMUM LOW FLOW OF 0.5 GPM AND HIGH FLOW OF AT LEAST 18 GPM MUST BE INSTALLED AND VISIBLE UPON INSPECTION, ON ALL RESIDENTIAL INSTALLATIONS. COMMERCIAL JOBS MUST USE PRESSURE REGULATED HEADS.
ALL REQUIRED TREES MUST BE BAGGED OR BUBBLED ON THEIR OWN ZONE. HEADS IN AREAS LESS THAN TEN FEET MUST BE ONE OF TWO ACCEPTED HEADS. ALL IRRIGATION IS SUBJECT TO FIELD INSPECTIONS. FRONT, BACK AND BOTH SIDE MICRO ZONES MUST HAVE THEIR OWN ZONES. PLANS SHOWING ZONE CALCULATIONS MUST BE WITH THE PERMIT AT FINAL INSPECTION.