Permit Info
Short Description:
4397 AC, 5299 SF, SFR / 2 STORY
Approved Date:
10/20/2017
Expiration Date:
10/20/2018
Notes:
4397 AC, 5299 SF, SFR / 2 STORY
10/21/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
014. BEAMS=10"W X 28"D.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 4BR, 2BA, GAME, MEDIA, WETBAR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RIDGEVIEW AT PANTHER CREEK PHASE 2 (CFR)
|
BF TESTER | JOSEPH WOLFE | (214)755-5268 | | 3017 KONET STREET | IRVING, TX 75060 |
OWNER | YERRAMSETTY SURENDER & | ()- | | ANITHA MUNASWAMY | FRISCO, TX 75035-0916 |
MAIL TO | YERRAMSETTY SURENDER & | ()- | | ANITHA MUNASWAMY | FRISCO, TX 75035-0916 |
APPLICANT | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | jkillebrew@metrocode.com | | FT WORTH, TX 76116 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dthompson@lsmech.com | | RICHARDSON, TX 75081 |
STRUCT ENG | ERIC L DAVIS ENGINEERING INC | (972)564-0592 | ericdavis@eldengineering.com | PO BOX 2637 | FORNEY, TX 75126 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/20/2017
| | 10/20/2017 | |
More Info
|
There are currently no reviews on this record.