Permit Info
Short Description:
4076 AC, 4961 SF, SFR / 2 STORY
Approved Date:
10/20/2017
Expiration Date:
10/20/2018
Notes:
4076 AC, 4961 SF, SFR / 2 STORY
4/6/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
024. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(4/6/2017 2:49 PM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
ARBORS AT WILLOW BAY PHASE V THE (CFR)
|
BF TESTER | JOSEPH WOLFE | (214)755-5268 | | 3017 KONET STREET | IRVING, TX 75060 |
OWNER | KARNATI RAVI KIRAN & PADMAVATHI NUTHALAP | ()- | | | FRISCO, TX 75035-8028 |
MAIL TO | KARNATI RAVI KIRAN & PADMAVATHI NUTHALAP | ()- | | | FRISCO, TX 75035-8028 |
APPLICANT | GEHAN HOMES LTD | (214)801-8427 | dpenney@gehanhomes.com | 15725 North Dallas Pkwy ste 300 | FRISCO, TX 75035 |
CONTRACTOR | GEHAN HOMES LTD | (214)801-8427 | dpenney@gehanhomes.com | 15725 North Dallas Pkwy ste 300 | FRISCO, TX 75035 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
ENGINEER | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NELROD CO | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | AIRTRON INC. | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8322 | rtoole@lsmech.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/20/2017
| | 10/20/2017 | |
More Info
|
There are currently no reviews on this record.