Permit Info
Short Description:
4212 AC, 5077 SF, SFR / 2 STORY
Approved Date:
10/13/2017
Expiration Date:
10/13/2018
Notes:
4212 AC, 5077 SF, SFR / 2 STORY
10/6/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (06/18/13) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
030. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES PHASE III (CFR)
|
BF TESTER | JOSEPH WOLFE | (214)755-5268 | | 3017 KONET STREET | IRVING, TX 75060 |
OWNER | ABRAHAM KEVIN & | ()- | | MINU R SABU | FRISCO, TX 75035-0836 |
MAIL TO | ABRAHAM KEVIN & | ()- | | MINU R SABU | FRISCO, TX 75035-0836 |
APPLICANT | LENNAR HOMES | (469)587-5200 | dfwpermits@lennar.com | | IRVING, TX 75063 |
CONTRACTOR | LENNAR HOMES | (469)587-5200 | dfwpermits@lennar.com | | IRVING, TX 75063 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
ENGINEER | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | jkillebrew@metrocode.com | | FT WORTH, TX 76116 |
MECH. CTR. | TEMPO MECHANICAL SERVICES (mech) | (972)579-2000 | danny.buchanan@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | CATHEDRAL PLUMBING OF TEXAS LLC | (972)446-2500 | luis.u@cathedralplumbingtx.com | | FRISCO, TX 75035 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/13/2017
| | 10/13/2017 | |
More Info
|