Permit Info
Short Description:
1 BF FIRE 5356 AC, 7300 SF, SFR / 2 STORY
Expiration Date:
8/25/2018
Notes:
1 BF FIRE 5356 AC, 7300 SF, SFR / 2 STORY
2/24/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
024. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF >= 5.7 SQFT. MINIMUM NET CLEAR HEIGHT OF 24" & NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW >= 5.0SQFT).
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS PHASE ELEVEN B (CFR)
|
BF TESTER | THOMAS STEHLIK | (817)360-9089 | TJSTEHLIK@HOTMAIL.COM | 1431 STONY VALLEY | PONDER, TX 76259 |
OWNER | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
MAIL TO | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
APPLICANT | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-1077 | crussell@landonhomes.com | | PLANO, TX 75093 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
ENGINEER | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | kellyn.haughnout@resservices.com | | DALLAS, TX 75220 |
PLUM. CONT. | L & S MECHANICAL (plumb) | (214)393-8322 | rtoole@lsmech.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES INC | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
9/5/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/25/2017
| | 8/25/2017 | |
More Info
|
There are currently no reviews on this record.