Permit Info
Short Description:
1 BF WATER SPOFT; 4808 AC, 5971 SF, SFR / 2 STORY
Expiration Date:
8/7/2018
Notes:
1 BF WATER SPOFT; 4808 AC, 5971 SF, SFR / 2 STORY
2/16/2017 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
025. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
046. SECOND STORY WINDOWS (SIZE & TYPE) MUST INCLUDE HEAD HEIGHT
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
053. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF THIS ISSUED BUILDING PERMIT.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(2/16/2017 10:45 AM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PHILLIPS CREEK RANCH PHASE 4A
|
BF TESTER | BRANDON RICHIE | (469)258-7720 | | 8587 SOUTHWESTERN BLVD | DALLAS, TX 75206 |
OWNER | DREES CUSTOM HOMES, LP | ()- | | | IRVING, TX 75038-2230 |
MAIL TO | DREES CUSTOM HOMES, LP | ()- | | | IRVING, TX 75038-2230 |
APPLICANT | DREES CUSTOM HOMES | (972)953-4439 | pnabors@dreeshomes.com | | IRVING, TX 75038 |
CONTRACTOR | DREES CUSTOM HOMES | (972)953-4439 | pnabors@dreeshomes.com | | IRVING, TX 75038 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
ENGINEER | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
HERS PROVIDE | TOPBUILD HOME SERVICES/TB HOME SERVICES | (386)304-2222 | LICENSEHELP@TRUETEAM.COM | | DAYTONA BEACH, FL 32114 |
MECH. CTR. | TEMPO MECHANICAL SERVICES (mech) | (972)579-2015 | jessica.aguilar@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | LASITER PLUMBING | (817)831-4245 | DAVIDL@LASITER.COM | | HALTOM CITY, TX 76117 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|