Permit Info
Short Description:
1 WAT SOF 3442 AC, 4027 SF, SFR / 2 STORY
Expiration Date:
6/23/2018
Notes:
1 WAT SOF 3442 AC, 4027 SF, SFR / 2 STORY
5/14/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
013. BEAMS=10"W X 26"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 1BR, 1BA, BONUS ROOM.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS PHASE SEVENTEEN (CFR)
|
BF TESTER | JOSEPH WOLFE | (214)755-5268 | | 3017 KONET STREET | IRVING, TX 75060 |
OWNER | SHARMA DEEPAK & PRADNYA | ()- | | | FRISCO, TX 75035-7743 |
MAIL TO | SHARMA DEEPAK & PRADNYA | ()- | | | FRISCO, TX 75035-7743 |
APPLICANT | K HOVNANIAN HOMES | (469)387-8374 | cfarrell@khov.com | 6633 Detweiller | Frisco, TX 75035 |
CONTRACTOR | K HOVNANIAN HOMES | (469)387-8374 | cfarrell@khov.com | 6633 Detweiller | Frisco, TX 75035 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | BELL MECHANICAL SERVICES | (225)752-8538 | mike@bellmechanical.com | | BATON ROUGE, LA 70879 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | | DALLAS, TX 75201 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/23/2017
| | 6/23/2017 | |
More Info
|
There are currently no reviews on this record.