Permit Info
Short Description:
1 BF WATER SOFT 4734 AC, 5797 SF, SFR / 2 STORY
Expiration Date:
6/8/2018
Notes:
1 BF WATER SOFT 4734 AC, 5797 SF, SFR / 2 STORY
10/30/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
037. DRIVEWAY SLOPE MUST NOT EXCEED 10%; PLOT PLANS WITH GRADES ARE REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
055. FUEL BURNING APPLIANCE INSTALLATION MUST BE CODE COMPLIANT.
058. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER ENCLOSED SHEET (CZO PG 188)
(2/28/2013 11:20 AM MAC)
* CHANGE PLUMBER TO L & S
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS PHASE SEVEN (CFR)
|
BF TESTER | JOSEPH WOLFE | (214)755-5268 | | 3017 KONET STREET | IRVING, TX 75060 |
OWNER | METLA SHANKAR & | ()- | | JAYASRI BANDIA | FRISCO, TX 75035-0486 |
MAIL TO | METLA SHANKAR & | ()- | | JAYASRI BANDIA | FRISCO, TX 75035-0486 |
APPLICANT | LANDON HOMES | (214)619-2930 | CRUSSELL@LANDONHOMESUSA.COM | | PLANO, TX 75093 |
CONTRACTOR | LANDON HOMES | (214)619-2930 | CRUSSELL@LANDONHOMESUSA.COM | | PLANO, TX 75093 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | brian.hartley@ies-co.com | SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
MECH. CTR. | AIRTRON INC | (214)355-1232 | SHARON.JOHNSON@RESSERVICES.COM | | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dgugliotta@lsplumb.com | SUITE 210 | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.