1 BF FIRE 5856 AC, 6980 SF, SFR / 2 STORY
9/7/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (06/18/13) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
**** 2ND STORY - GR, 3BR, & 3BA ****
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SHADDOCK CREEK ESTATES PHASE 6B
|
OWNER | SHADDOCK HOMES LTD | ()- | | | PLANO, TX 75093-4381 |
MAIL TO | SHADDOCK HOMES LTD | ()- | | | PLANO, TX 75093-4381 |
APPLICANT | SHADDOCK HOMES LTD | (972)526-7700 | permits@shaddockhomes.com | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)526-7700 | permits@shaddockhomes.com | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC INC | (972)941-8600 | wstory@metrotechelectric.com | | WYLIE, TX 75098 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |