Permit Info
Short Description:
1 BF - WATER SOFT 3480 AC, 4202 SF, SFR / 2 STORY
Expiration Date:
4/5/2019
Notes:
1 BF - WATER SOFT 3480 AC, 4202 SF, SFR / 2 STORY
6/3/2016 12:00:00 AM
*** FENCING RESTRICTIONS APPLY TO THIS LOT (SEE PD-202 AND ZONING ORDINANCES) ***
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 3 RISERS OR MORE REQUIRE A HANDRAIL
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 3BR, 2BA, GAME, MEDIA, CARD AREA.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PHILLIPS CREEK RANCH WATERTON PHASE 4
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | PALAKURTY, BHARADWAJA & VUMMETHALA, HERI | ()- | | | FRISCO, TX 75034 |
MAIL TO | PALAKURTY, BHARADWAJA & VUMMETHALA, HERI | ()- | | | FRISCO, TX 75034 |
APPLICANT | CALATLANTIC HOMES | (972)590-2433 | PermitDallas@stanpac.com | | IRVING, TX 75039 |
CONTRACTOR | CALATLANTIC HOMES | (972)590-2433 | PermitDallas@stanpac.com | | IRVING, TX 75039 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES | (972)292-1478 | MATTGOLDBERG@IN-CHARGE.ELECTRIC.COM | | LEWISVILLE, TX T5057 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | jkillebrew@metrocode.com | | FT WORTH, TX 76116 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | L & S PLUMBING (plumb) | (214)393-8322 | cguyton@lsmech.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING SERVICES | (214)451-6630 | tchildress@cesglobal.com | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/18/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/16/2018
| | 5/18/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/5/2017
| | 4/5/2017 | |
More Info
|
There are currently no reviews on this record.