Permit Info
Short Description:
1 BF WATER SOFTENER - 3546 AC, 4206 SF, SFR / 2 STORY
Expiration Date:
4/7/2019
Notes:
1 BF WATER SOFTENER - 3546 AC, 4206 SF, SFR / 2 STORY
9/11/2014 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
011. BEAMS=10"W X 26"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
055. WRITTEN COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO IN THE PERMIT POUCH.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2ND FLOOR: 3BR, 2BA, GAME, MEDIA
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
QUAIL MEADOW VILLAGE PHASE III
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | MUDIGONDA, NAGA VENKATA MALLIKARJUN RAO | ()- | | | FRISCO, TX 75034-0059 |
MAIL TO | MUDIGONDA, NAGA VENKATA MALLIKARJUN RAO | ()- | | | FRISCO, TX 75034-0059 |
APPLICANT | LENNAR HOMES | (469)587-5200 | dfwpermits@lennar.com | | IRVING, TX 75063 |
CONTRACTOR | LENNAR HOMES | (469)587-5200 | dfwpermits@lennar.com | | IRVING, TX 75063 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | energy@metrocode.com | | FT WORTH, TX 76102 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | david.gannon@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | CATHEDRAL PLUMBING OF TEXAS LL | (972)446-2500 | luis.u@cathedralplumbingtx.com | | FRISCO, TX 75035 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | | | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/31/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/31/2018
| | 5/31/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/7/2017
| | 4/7/2017 | |
More Info
|
There are currently no reviews on this record.