Permit Info
Short Description:
2228 AC, 2776 SF, SFR / 1 STORY
Expiration Date:
4/5/2018
Notes:
2228 AC, 2776 SF, SFR / 1 STORY
6/30/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (06/18/13) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
013. BEAMS=10"W X 26"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
025. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
026. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
027. WINDOW BOX-OUTS WITH SIDING & TRIM MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
BELMONT WOODS (CFR)
|
BF TESTER | PATRICK RYAN | (972)442-4864 | GARNOLD@MLJLANDSCAPING.COM | NORTH TEXAS LAWN & LANDSCAPE | ROCKWALL, TX 75087 |
OWNER | IMPRESSION HOMES LLC | ()- | | | SOUTHLAKE, TX 76092-0726 |
MAIL TO | IMPRESSION HOMES LLC | ()- | | | SOUTHLAKE, TX 76092-0726 |
APPLICANT | IMPRESSION HOMES | (817)717-5103 | PERMITS@IMPRESSIONHOMES.NET | | SOUTHLAKE, TX 76092 |
CONTRACTOR | IMPRESSION HOMES | (817)717-5103 | PERMITS@IMPRESSIONHOMES.NET | | SOUTHLAKE, TX 76092 |
ELECT. CTR. | CREST ELECTRICAL SOLUTIONS LLC | (817)795-0858 | chad@fwcrest.com | | ARLINGTON, TX 76011 |
HERS PROVIDE | TEXAS HOME ENERGY PROFESSIONAL | (817)312-8769 | JAHELM@GMAIL.COM | | HASLET, TX 76052 |
MECH. CTR. | TEMPO MECHANICAL SERVICES (mec | (972)579-2000 | danny.buchanan@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | KEN-MAN PLUMBING | (817)453-8032 | kbennett@ken-mancorp.com | | MANSFIELD, TX 76063 |
STRUCT ENG | NORTEX FOUNDATION DESIGNS INC | (817)379-0866 | info@nortexfoundation.com | | FORT WORTH, TX 76244 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.