Permit Info
Short Description:
1 BF WATER SOFT 3954 AC, 4610 SF, SFR / 2 STORY
Expiration Date:
2/9/2019
Notes:
1 BF WATER SOFT 3954 AC, 4610 SF, SFR / 2 STORY
4/25/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
STONELAKE ESTATES WEST PHASE II (CFR)
|
BF TESTER | DON MCCLENDON | (972)632-7979 | BACKFLOWTESTER@OUTLOOK.COM | 2941 DOG LEG TRL | MCKINNEY, TX 75069 |
OWNER | KUMAR DEEPAK & ADITI GOEL | ()- | | | FRISCO, TX 75035-0189 |
MAIL TO | KUMAR DEEPAK & ADITI GOEL | ()- | | | FRISCO, TX 75035-0189 |
APPLICANT | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | BECKY.COLLIER@IES-CO.COM | 713 TOWER LANE SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | 1255 W 15TH STE 100 | PLANO, TX 75075 |
MECH. CTR. | STARN AIR INC | (214)221-1313 | STARNAIRINC@AOL.COM | | GARLAND, TX 75042 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | | RICHARDSON, 75081 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
2/16/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/15/2018
| | 2/15/2018 | |
More Info
|
BACKFLOW | APPROVED |
2/9/2017
| | 2/9/2017 | |
More Info
|
There are currently no reviews on this record.