Permit Info
Short Description:
1 BF FIRE 5549 AC, 6707 SF, SFR / 2 STORY
Expiration Date:
11/2/2018
Notes:
1 BF FIRE 5549 AC, 6707 SF, SFR / 2 STORY
1/20/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SHADDOCK CREEK ESTATES PHASE 6B
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | EARLY, ROBERT & KRISTIN | ()- | | | FRISCO, TX 75033-3091 |
MAIL TO | EARLY, ROBERT & KRISTIN | ()- | | | FRISCO, TX 75033-3091 |
APPLICANT | SHADDOCK HOMES LTD | (972)526-7700 | tracy@shaddockhomes.com | | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)526-7700 | tracy@shaddockhomes.com | | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/15/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
11/3/2016
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/8/2017
| | 12/8/2017 | |
More Info
|
BACKFLOW | APPROVED |
11/2/2016
| | 11/2/2016 | |
More Info
|
There are currently no reviews on this record.