Permit Info
Short Description:
1 BF FIRE 5559 AC, 7075 SF, SFR / 2 STORY
Approved Date:
12/28/2017
Expiration Date:
11/2/2018
Notes:
1 BF FIRE 5559 AC, 7075 SF, SFR / 2 STORY
1/13/2016 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
(1/13/2016 10:20 AM JC)
Grade Beams : 10" x 28". Piers 12" dia., belled to 36" with vert. rebar per found. plan sch'l.
(2/1/2016 8:13 AM JC)
Removed piers from the foundation design. Grade Beams increased from 10" x 28" to 10" x 30".
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SHADDOCK CREEK ESTATES PHASE 6B
|
| BF TESTER | GARY MERIMON | (972)222-7216 | GMERIMON@AOL.COM | 1315 HILLCREST DR | ALLEN, TX 75002 |
| OWNER | JONES, STEVEN DONALD & OLIVIA LOUISE | ()- | | | FRISCO, TX 75034 |
| MAIL TO | JONES, STEVEN DONALD & OLIVIA LOUISE | ()- | | | FRISCO, TX 75034 |
| APPLICANT | SHADDOCK HOMES LTD | (972)526-7700 | tracy@shaddockhomes.com | | PLANO, TX 75093 |
| CONTRACTOR | SHADDOCK HOMES LTD | (972)526-7700 | tracy@shaddockhomes.com | | PLANO, TX 75093 |
| ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
| FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
| HERS PROVIDE | HANSON CONSTRUCTION CONSULTING | (214)544-3325 | | 2353 STICKHORSE INC | McKINNEY, TX 75071 |
| MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
| PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
| STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
12/28/2017
|
| BACK FLOW FORM REVIEW |
$0.00
|
|
| BACK FLOW FORM REVIEW |
$25.00
|
11/3/2016
|
| Total Fees |
|
Charged: $50.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
12/28/2017
| | 12/28/2017 | |
More Info
|
| BACKFLOW | APPROVED |
11/2/2016
| | 11/2/2016 | |
More Info
|
There are currently no reviews on this record.