Permit Info
Short Description:
2 BF - 5280 AC, 6563 SF, SFR / 2 STORY
Expiration Date:
9/16/2018
Notes:
2 BF - 5280 AC, 6563 SF, SFR / 2 STORY
12/11/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
016. BEAMS=10"W X 30"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
032. ALL SIDING, TRIM, SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL; (OR) ENGINEERED/TREATED WOOD PRODUCT.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 3 RISERS OR MORE REQUIRE A HANDRAIL
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
NEWMAN VILLAGE PHASE 3
|
BF TESTER | CHARLES JESTIS | (214)535-3341 | CJESTIS88@GMAIL.COM | 3025 OAK MEADOW DR | FLOWER MOUND, TX 75028 |
OWNER | MATTHEWS, KEVIN L & LORIS S | ()- | | | FRISCO, TX 75033 |
MAIL TO | MATTHEWS, KEVIN L & LORIS S | ()- | | | FRISCO, TX 75033 |
APPLICANT | DARLING HOMES OF TEXAS LLC | (972)624-4100 | stremont@darlinghomes.com | | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES OF TEXAS LLC | (972)624-4100 | stremont@darlinghomes.com | | FRISCO, TX 75034 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | FOX ENERGY SPECIALIST / THE NE | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | danny.buchanan@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | CDMARQUARDT@MLAWDFW.COM | | AUSTIN, TX 78758 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/4/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
10/3/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/30/2017
| | 9/30/2017 | |
More Info
|
BACKFLOW | APPROVED |
10/27/2016
| | 10/27/2016 | |
More Info
|
BACKFLOW | APPROVED |
9/16/2016
| | 9/16/2016 | |
More Info
|
There are currently no reviews on this record.