Permit Info
Short Description:
1 BF - FIRE PROT. - 2238 AC, 2892 SF, SFR / 1 STORY
Status:
RES LETTER ONE SENT
Expiration Date:
5/19/2018
Notes:
1 BF - FIRE PROT. - 2238 AC, 2892 SF, SFR / 1 STORY
12/21/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
016. BEAMS=10"W X 30"D.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
033. ALL SIDING,TRIM,SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL.
039. BOTH INTERIOR AND EXTERIOR STAIRS OF 3 RISERS OR MORE REQUIRE A HANDRAIL
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
THE CANALS AT GRAND PARK-NORTH PHASE 1B NORTH
|
BF TESTER | CHRISTOPHER GAFFORD | (972)242-2229 | | 2605 DAISY LANE | ROWlETT, TX 75089 |
OWNER | THOMPSON, MICHAEL & CINNAMON | ()- | | | FRISCO, TX 75034-0211 |
MAIL TO | THOMPSON, MICHAEL & CINNAMON | ()- | | | FRISCO, TX 75034-0211 |
APPLICANT | CB JENI HOMES | (214)383-1115 | bwilliams@cbjenihomes.com | | PLANO, TX 75093 |
CONTRACTOR | CB JENI HOMES | (214)383-1115 | bwilliams@cbjenihomes.com | | PLANO, TX 75093 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)701-1057 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | ENERGY CODE SOLUTIONS | (817)412-0351 | ENERGYINSPECT@ATT.NET | | EULESS, TX 76040 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | CATHEDRAL PLUMBING OF TEXAS LL | (972)446-2500 | luis.u@cathedralplumbingtx.com | | FRISCO, TX 75035 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$25.00
|
7/31/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
6/1/2016
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
7/25/2017
| | 7/25/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/19/2016
| | 5/19/2016 | |
More Info
|
There are currently no reviews on this record.