Permit Info
Short Description:
1 BF WATER SOFT- *MODEL* 5037 AC, 5989 SF, SFR / 2 STORY
Status:
RES LETTER ONE SENT
Expiration Date:
5/19/2018
Notes:
1 BF WATER SOFT- *MODEL* 5037 AC, 5989 SF, SFR / 2 STORY
5/9/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
ADD GABLE TO MASTER BATHEROOM ELEVATION FOR 5.0X2.6 EYEBROW WINDOW AND ADD BARREL VAULT CEILING TO MASTER BATH.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS #1 (CFR)
|
BF TESTER | CHARLES SMITH | (940)206-4027 | | 1326 SHERMAN | DENTON, TX 76209 |
OWNER | REDDI RAVI & SUDAMA M | ()- | | | FRISCO, TX 75035-7364 |
MAIL TO | REDDI RAVI & SUDAMA M | ()- | | | FRISCO, TX 75035-7364 |
APPLICANT | NEW CASTLE HOMES | (214)987-9158 | | | DALLAS, TX 75225 |
CONTRACTOR | NEW CASTLE HOMES | (214)987-9158 | | | DALLAS, TX 75225 |
ELECT. CTR. | POTTER ELECTRIC | (972)442-1600 | claypottr@aol.com | 709 HWY 78 SOUTH | FARMERSVILLE, TX 75442 |
HERS PROVIDE | TEXENERGY SOLUTIONS | (972)579-2009 | mendozam@texenergy.org | 2611 E PIONEER DR | IRVING, TX 75061 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | SHARON.JOHNSON@RESSERVICES.COM | | DALLAS, TX 75243 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/30/2017
| | 6/2/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/19/2016
| | 5/19/2016 | |
More Info
|
There are currently no reviews on this record.