Permit Info
Short Description:
1 BF - 4083 AC, 4746 SF, SFR / 2 STORY
Expiration Date:
4/14/2019
Notes:
1 BF - 4083 AC, 4746 SF, SFR / 2 STORY
7/30/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
014. BEAMS=10"W X 28"D.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
046. SECOND STORY WINDOWS (SIZE & TYPE) MUST INCLUDE HEAD HEIGHT
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RIDGEVIEW AT PANTHER CREEK PHASE 2 (CFR)
|
BF TESTER | CHRIS JONES | (214)597-1760 | chrisjonesbackflow@gmail.com | 1931 MIDDLE GLEN DR | CARROLLTON, TX 75007 |
OWNER | PABBISETTY BALAJI SRINIVAS & VENKATA LAK | ()- | | | FRISCO, TX 75035-0726 |
MAIL TO | PABBISETTY BALAJI SRINIVAS & VENKATA LAK | ()- | | | FRISCO, TX 75035-0726 |
APPLICANT | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
CONTRACTOR | FIRST TEXAS CUSTOM HOMES | (214)613-3400 | AGUTIERREZ@FIRSTTEXASHOMES.COM | | DALLAS, TX 75201 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | jkillebrew@metrocode.com | | FT WORTH, TX 76116 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | dthompson@lsmech.com | | RICHARDSON, 75081 |
STRUCT ENG | ERIC L DAVIS ENGINEERING | (972)564-0592 | robp@eldengineering.com | | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/27/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/15/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/26/2018
| | 4/27/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/12/2017
| | 5/12/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/14/2016
| | 4/14/2016 | |
More Info
|
There are currently no reviews on this record.