Permit Info
Short Description:
1 BF FIRE PROT, 5648 AC, 7518 SF, SFR / 2 STORY
Expiration Date:
9/2/2018
Notes:
1 BF FIRE PROT, 5648 AC, 7518 SF, SFR / 2 STORY
1/21/2011 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
2nd FLOOR: 1-BED ROOM, 1-BATH ,STORAGE AND MEDIA WITH A WET BAR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #1 (CFR)
|
| BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
| OWNER | ROSS CHARLES S & ANN A REV TR | ()- | | CHARLES S ROSS & ANN A ROSS TR | FRISCO, TX 75034-7230 |
| MAIL TO | ROSS CHARLES S & ANN A REV TR | ()- | | CHARLES S ROSS & ANN A ROSS TR | FRISCO, TX 75034-7230 |
| APPLICANT | CUSTOM HOMES OF TEXAS | (817)491-3133 | BRANDON@CUSTOMHOMESOFTEXAS.COM | 102 N AMERICAN LN | ROANOKE, TX 76262 |
| CONTRACTOR | CUSTOM HOMES OF TEXAS | (817)491-3133 | BRANDON@CUSTOMHOMESOFTEXAS.COM | 102 N AMERICAN LN | ROANOKE, TX 76262 |
| ELECT. CTR. | IN CHARGE ELCTRICAL SERVICES L | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | 3101 US HWY 183 | LIBERTY HILL, TX 78642 |
| FIRE CONTACT | G&S FIre Systems | (817)988-1239 | | PO Box 182192 | Arlington, TX 76096 |
| HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | sshain@foxenergyspecialists.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
| MECH. CTR. | STRITTMATTER AIR CONDITIONING | (940)565-5890 | | 2700 CHEBI LANE | DENTON, TX 76209 |
| PLUM. CONT. | DELAROSA PLUMBING INC | (940)465-4546 | ABRAHAM0314@MSN.COM | 5904 MEADOWGLEN DRIVE | ARGYLE, TX 76226 |
| STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
10/11/2017
|
| Total Fees |
|
Charged: $25.00
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
10/5/2017
| | 10/5/2017 | |
More Info
|
| BACKFLOW | APPROVED |
9/2/2016
| | 9/2/2016 | |
More Info
|