Permit Info
Short Description:
1 BF FIRE PROT-8604 AC, 11506 SF, SFR / 2 STORY
Expiration Date:
4/14/2019
Notes:
1 BF FIRE PROT-8604 AC, 11506 SF, SFR / 2 STORY
10/19/2011 12:00:00 AM
(10/19/2011 4:09 PM JC)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
(10/19/2011 4:13 PM JC)
2nd. story w/ (3) bedrooms, (4) baths, laundry, game, exercise & mech. rooms.
Vertical height from avg. fin. grade to highest ridge not to exceed 40'.
Both grade beams and struct. slab with 8" void boxes below.
(SLC)
see b12-2669 for completion
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE #17 (CFR)
|
BF TESTER | DANNY R SMITHERMAN | (972)647-8172 | | 1171 RUGGLES DR | GRANDPRAIRIE, TX 75050 |
OWNER | SOHOSKY JARROD & DARLENE A | ()- | | | FRISCO, TX 75034 |
MAIL TO | SOHOSKY JARROD & DARLENE A | ()- | | | FRISCO, TX 75034 |
APPLICANT | BENTLEY PREMIER BUILDERS | (214)501-4084 | BDONOVAN@BENTLEYPREMIER.COM | | PLANO, TX 75093 |
CONTRACTOR | MARTIN RAYMOND HOMES | (972)380-8882 | MARTINRAYMONDHOMES@GMAIL.COM | POB 260118 | PLANO, TX 75026 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | | | ALLEN, TX 75013 |
MECH. CTR. | ADVENT AIR CONDITIONING, INC | (972)221-4373 | mlewis@adventair.com | | LEWISVILLE, TX 75057 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/10/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/2/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
There are currently no reviews on this record.