Permit Info
Short Description:
1 BF FIRE PROT-4893 AC, 6182 SF, SFR / 2 STORY
Expiration Date:
8/29/2018
Notes:
1 BF FIRE PROT-4893 AC, 6182 SF, SFR / 2 STORY
10/31/2014 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH SPOT GRADES ARE REQUIRED.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
014. BEAMS=10"W X 30"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
027. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
046. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
047. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
NEWMAN VILLAGE PHASE 2B
|
BF TESTER | KOLTON HODGES | ()- | | 1224 BLACKHAWK DR | HASLET, TX 76057 |
OWNER | CUNNINGHAM, ROSALIA & JIMMIE L | ()- | | AND ROSALIA C CUNNUNGHAM REVOC | FRISCO, TX 75033 |
MAIL TO | CUNNINGHAM, ROSALIA & JIMMIE L | ()- | | AND ROSALIA C CUNNUNGHAM REVOC | FRISCO, TX 75033 |
APPLICANT | DARLING HOMES OF TEXAS LLC | (972)624-4100 | stremont@darlinghomes.com | | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES OF TEXAS LLC | (972)624-4100 | stremont@darlinghomes.com | | FRISCO, TX 75034 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | david.gannon@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | MLAW CONSULTANTS & ENGINEERS | (512)835-7000 | CDMARQUARDT@MLAWDFW.COM | | AUSTIN, TX 78758 |
|
BACK FLOW FORM REVIEW |
$25.00
|
9/1/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/25/2017
| | 8/25/2017 | |
More Info
|
BACKFLOW | APPROVED |
8/29/2016
| | 8/29/2016 | |
More Info
|
There are currently no reviews on this record.