Permit Info
Short Description:
1 BF FIRE PROT. 6465 AC, 8394 SF, SFR / 2 STORY
Expiration Date:
1/14/2019
Notes:
1 BF FIRE PROT. 6465 AC, 8394 SF, SFR / 2 STORY
10/16/2013 12:00:00 AM
(10/16/2013 8:31 AM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12%; PLOT PLANS WITH GRADES ARE REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(10/16/2013 8:33 AM JC)
Attic area shown as future living space with live load capacity as shown is treated as AC area with fire protection.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
| BF TESTER | THOMAS STEHLIK | (214)350-1755 | TJSTEHLIK@HOTMAIL.COM | PO BOX 630886 | IRVING, TX 75063 |
| OWNER | YOUNG WILLIAM NOEL | ()- | | | FRISCO, TX 75034-7436 |
| MAIL TO | YOUNG WILLIAM NOEL | ()- | | | FRISCO, TX 75034-7436 |
| APPLICANT | ENDURANCE CUSTOM HOMES LLC | (469)287-1865 | brian.hunt@endurancehomes.com | 5416 Southern Hills Dr. | FRISCO, TX 75034 |
| CONTRACTOR | ENDURANCE CUSTOM HOMES LLC | (469)287-1865 | brian.hunt@endurancehomes.com | 5416 Southern Hills Dr. | FRISCO, TX 75034 |
| ELECT. CTR. | ODYSSEY ELECTRIC LLC | (817)269-2750 | TLF122@YAHOO.COM | | NORTH RICHLAND HILLS, TX 76182 |
| FIRE CONTACT | RES COM FIRE SYSTEMS | (214)350-1755 | | P.O. BOX 630886 | IRVING, TX 75068 |
| HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | energy@metrocode.com | | FT WORTH, TX 76102 |
| MECH. CTR. | PROSTAR AIR | (972)245-0700 | | | CARROLLTON, TX |
| PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
| STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75082 |
|
| BACK FLOW FORM REVIEW |
$25.00
|
4/24/2018
|
| CREDIT CARD FEE |
$0.50
|
4/24/2018
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/16/2017
|
| BACK FLOW FORM REVIEW |
$25.00
|
1/17/2017
|
| Total Fees |
|
Charged: $75.50
Balance Due: $0.00
|
|
| BACKFLOW | APPROVED |
4/24/2018
| | 4/24/2018 | |
More Info
|
| BACKFLOW | APPROVED |
1/14/2017
| | 1/14/2017 | |
More Info
|
| BACKFLOW | BF FAILED |
1/5/2017
| | 1/5/2017 | |
More Info
|
There are currently no reviews on this record.