Permit Info
Short Description:
2 BF FIRE PROT 5079 AC, 6341 SF, SFR / 2 STORY
Expiration Date:
2/6/2020
Notes:
1 BF FIRE PROT 5079 AC, 6341 SF, SFR / 2 STORY
5/1/2014 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 28"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2nD FLOOR: 3-BED ROOMS, 3-BATHS, GAME & MEDIA ROOMS WITH WET BAR OPTION.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
NEWMAN VILLAGE PHASE 2B
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | BROKISH, PETER ANDREW & PATRIC | ()- | | | FRISCO, TX 75033 |
MAIL TO | BROKISH, PETER ANDREW & PATRIC | ()- | | | FRISCO, TX 75033 |
APPLICANT | BELCLAIRE HOMES | (972)410-5701 | csheffield@alhltd.com | | LEWISVILLE, TX 75056 |
CONTRACTOR | BELCLAIRE HOMES | (972)410-5701 | csheffield@alhltd.com | | LEWISVILLE, TX 75056 |
ELECT. CTR. | C & B ELECTRIC / LARRY CAUSEY | (972)790-0707 | clindow@cbeltx.com | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
2/19/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/25/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
4/12/2017
|
CREDIT CARD FEE |
$0.50
|
4/12/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
2/8/2016
|
Total Fees |
Charged: $100.50
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/15/2018
| | 5/25/2018 | |
More Info
|
BACKFLOW | APPROVED |
2/13/2018
| | 2/13/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/10/2017
| | 4/10/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/6/2016
| | 2/6/2016 | |
More Info
|
There are currently no reviews on this record.