Permit Info
Short Description:
1 bf fire prot 4321 AC, 5552 SF, SFR / 2 STORY
Expiration Date:
12/23/2018
Notes:
1 bf fire prot 4321 AC, 5552 SF, SFR / 2 STORY
5/8/2015 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
005. RETAINING WALLS THREE (3) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
014. BEAMS=10"W X 28"D.
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
032. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
***2ND FLOOR - GR, M, 3BR, & 3-1/2 BA***
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
PARK PLACE ESTATES PHASE 3
|
BF TESTER | JEFFREY WORLEY | (972)699-7156 | | 1662 CR 1020 | RAVENNA, TX 75476 |
OWNER | BARBER, MICHAEL JAMES & MELISSA YVETTE | ()- | | | FRISCO, TX 75034-2302 |
MAIL TO | BARBER, MICHAEL JAMES & MELISSA YVETTE | ()- | | | FRISCO, TX 75034-2302 |
APPLICANT | BELCLAIRE HOMES | (972)410-5701 | abaker@alhltd.com | | LEWISVILLE, TX 75056 |
CONTRACTOR | BELCLAIRE HOMES | (972)410-5701 | abaker@alhltd.com | | LEWISVILLE, TX 75056 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES | (972)292-1478 | MATTGOLDBERG@IN-CHARGE.ELECTRIC.COM | | LEWISVILLE, TX T5057 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | rescomfire@sbcgloba.net | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)546-0160 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76011 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
STRUCT ENG | ERIC L DAVIS ENGINEERING | (972)564-0592 | robp@eldengineering.com | | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/26/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
1/12/2016
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/22/2017
| | 6/22/2017 | |
More Info
|
BACKFLOW | APPROVED |
12/23/2015
| | 12/23/2015 | |
More Info
|
There are currently no reviews on this record.