Permit Info
Short Description:
2 BF FIRE PROT - 5582 AC, 7415 SF, SFR / 2 STORY
Expiration Date:
12/10/2018
Notes:
2 BF FIRE PROT - 5582 AC, 7415 SF, SFR / 2 STORY
4/20/2015 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
006. MAX STRUCTURE HIEGHT FROM AVG FINISH GRADE 40'-0".
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
017. BEAMS=10"W X 32"D.
***PIERS: 12" DIA. W/VERT. REBAR PER PLAN SCHEDULE.***
023. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
034. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
047. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
048. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
052. AUTOMATIC FIRE SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | CHARLES JESTIS | (214)535-3341 | CJESTIS88@GMAIL.COM | 3025 OAK MEADOW DR | FLOWER MOUND, TX 75028 |
OWNER | CUTRER, MALCOLM W JR & KEEP, NATALIE M | ()- | | | FRISCO, TX 75033-2881 |
MAIL TO | CUTRER, MALCOLM W JR & KEEP, NATALIE M | ()- | | | FRISCO, TX 75033-2881 |
APPLICANT | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
CONTRACTOR | PREMIER RENOVATIONS INC | (214)484-1448 | construction@rondaviscustomhomes.com | | DALLAS, TX 75252 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | MONICAC@FOXELECTRIC.COM | | ARLINGTON, TX 76094 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | BACKFLOW@GSFIREPROTECTIONLLC.COM | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | | PLANO, TX 75075 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | aseutter@chapmanair.com | | DALLAS, TX 75238 |
PLUM. CONT. | RAGSDALE PLUMBING | (903)450-4959 | RAGSDALEPLUMBINGINC@YAHOO.COM | | GREENVILLE, TX 75404 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | | RICHARDSON, TX 75080 |
|
BACK FLOW FORM REVIEW |
$50.00
|
4/13/2018
|
BACK FLOW FORM REVIEW |
$50.00
|
5/19/2017
|
Total Fees |
Charged: $100.00
Balance Due: $0.00
|
There are currently no reviews on this record.