Permit Info
Short Description:
1 BF FIRE PROT 4962 AC, 6032 SF, SFR / 2 STORY
Expiration Date:
3/2/2019
Notes:
1 BF FIRE PROT 4962 AC, 6032 SF, SFR / 2 STORY
7/30/2012 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
028. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
NEWMAN VILLAGE PH ONE
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | GUZIEC, DOUGLAS A & MICHELLE J | ()- | | | FRISCO, TX 75033 |
MAIL TO | GUZIEC, DOUGLAS A & MICHELLE J | ()- | | | FRISCO, TX 75033 |
APPLICANT | AMERICAN LEGEND HOMES | (972)410-5701 | CSHEFFIELD@ALHLTD.COM | | LEWISVILLE, TX 75056 |
CONTRACTOR | AMERICAN LEGEND HOMES | (972)410-5701 | CSHEFFIELD@ALHLTD.COM | | LEWISVILLE, TX 75056 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/23/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
4/12/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/17/2018
| | 4/17/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/12/2017
| | 4/12/2017 | |
More Info
|
BACKFLOW | APPROVED |
3/2/2016
| | 3/2/2016 | |
More Info
|
There are currently no reviews on this record.