Permit Info
Short Description:
NO FIRE PROT. 4810 AC, 6359 SF, SFR / 2 STORY
Notes:
NO FIRE PROT. 4810 AC, 6359 SF, SFR / 2 STORY
2/2/2012 12:00:00 AM
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 30"D.
023. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(2/2/2012 1:11 PM JC)
2nd. story w/ (3) bedrooms, (2) baths & game rm.
(2/9/2012 11:06 AM JC)
Foudation re-design.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
OWNER | MEHTA, RINKU V & DANNY J | ()- | | | FRISCO, TX 75033 |
MAIL TO | MEHTA, RINKU V & DANNY J | ()- | | | FRISCO, TX 75033 |
APPLICANT | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | dawn@mchristopherinc.com | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
CONTRACTOR | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | dawn@mchristopherinc.com | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | BECKY.COLLIER@IES-CO.COM | 713 TOWER LANE SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | ACP ALLIED CONSTRUCTION PROFES | (214)227-9540 | TONYA@ENERGYACP.COM | 1900 ESPINOSA DRIVE | CARROLLTON, TX 75010 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | dripley@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | | WYLIE, TX 75098 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.