Permit Info
Short Description:
1 BF WATER SOFTENER 3564 AC, 4217 SF, SFR / 2 STORY
Expiration Date:
6/9/2018
Notes:
1 BF WATER SOFTENER 3564 AC, 4217 SF, SFR / 2 STORY
9/30/2014 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
011. BEAMS=10"W X 26"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
041. TEMPERED GLASS REQ'D AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
049. FUEL BURNING APPLIANCE INSTALLATION WITHIN AN AC AREA MUST BE CODE COMPLIANT.
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
059. DRIVEWAY, LEADWALK & GARAGE DOOR ENHANCEMENT & TREATMENT PER THE ENCLOSED
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
2nd FLOOR: 2-BED ROOMS, 1 1/2 BATHS & THEATER ROOM.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
QUAIL MEADOW VILLAGE PHASE III
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | TIKKA, RAVIKUMAR & KAVITHA PAR | ()- | | | FRISCO, TX 75034 |
MAIL TO | TIKKA, RAVIKUMAR & KAVITHA PAR | ()- | | | FRISCO, TX 75034 |
APPLICANT | LENNAR HOMES | (469)587-5200 | dfwpermits@lennar.com | | IRVING, TX 75063 |
CONTRACTOR | LENNAR HOMES | (469)587-5200 | dfwpermits@lennar.com | | IRVING, TX 75063 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | energy@metrocode.com | | FT WORTH, TX 76102 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | david.gannon@tempoair.com | | IRVING, TX 75061 |
PLUM. CONT. | CATHEDRAL PLUMBING OF TEXAS LL | (972)446-2500 | luis.u@cathedralplumbingtx.com | | FRISCO, TX 75035 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | | | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/10/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
6/29/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/29/2017
| | 6/29/2017 | |
More Info
|
BACKFLOW | APPROVED |
6/9/2016
| | 6/9/2016 | |
More Info
|
BACKFLOW | APPROVED |
6/12/2015
| | 6/12/2015 | |
More Info
|
There are currently no reviews on this record.