Permit Info
Short Description:
1 BF WATER SOFTENER 3977 AC, 4811 SF, SFR / 2 STORY
Expiration Date:
5/13/2019
Notes:
1 BF WATER SOFTENER 3977 AC, 4811 SF, SFR / 2 STORY
1/24/2014 12:00:00 AM
002. COMPLIANCE WITH THE 2012 BUILDING CODES, LOCAL AMENDMENTS AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 28"D.
021. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
030. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
043. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
044. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
056. LANDSCAPE IRRIGATION SYSTEM REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
057. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
2nd FLOOR: 2-BED ROOMS, 1 BATH, GAME & STORAGE CLOSET.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
ARBORS AT WILLOW BAY #3 (CFR)
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | RAMASUBRAMANIAN DINESH | ()- | | | FRISCO, TX 75035-6256 |
MAIL TO | RAMASUBRAMANIAN DINESH | ()- | | | FRISCO, TX 75035-6256 |
APPLICANT | AMERICAN LEGEND HOMES | (972)410-5701 | CSHEFFIELD@ALHLTD.COM | | LEWISVILLE, TX 75056 |
CONTRACTOR | AMERICAN LEGEND HOMES | (972)410-5701 | CSHEFFIELD@ALHLTD.COM | | LEWISVILLE, TX 75056 |
ELECT. CTR. | IN CHARGE ELECTRICAL SERVICES | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | | FRISCO, TX 75034 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | | FORT WORTH, TX 76109 |
MECH. CTR. | HOUK AIR CONDITIONING | (817)265-1191 | CGORE@HOUKAC.COM | | ARLINGTON, TX 76010 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | JSANCHEZ@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/31/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/13/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
5/19/2017
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/18/2018
| | 5/31/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/19/2017
| | 5/19/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/13/2016
| | 5/13/2016 | |
More Info
|
BACKFLOW | APPROVED |
5/13/2015
| | 5/13/2015 | |
More Info
|
There are currently no reviews on this record.